ITEM
HRS
COMPRESSOR RUN HOURS
HR.A1
Compressor A1 Run Hours
HR.A2
Compressor A2 Run Hours
HR.A3
Compressor A3 Run Hours
HR.B1
Compressor B1 Run Hours
HR.B2
Compressor B2 Run Hours
HR.B3
Compressor B3 Run Hours
ITEM
STRT
COMPRESSOR STARTS
ST.A1
Compressor A1 Starts
ST.A2
Compressor A2 Starts
ST.A3
Compressor A3 Starts
ST.B1
Compressor B1 Starts
ST.B2
Compressor B2 Starts
ST.B3
Compressor B3 Starts
ITEM
VERS
SOFTWARE VERSION NUMBERS
MBB
CESR131461-xx-xx
RXB
CESR131465-xx-xx
EXB
CESR131465-xx-xx
CEM
CESR131174-xx-xx
CXB
CESR131173-xx-xx
SCB
CESR131226-xx-xx
VFD1
VERSION-313D
VFD2
VERSION-313D
MARQ
CESR131171-xx-xx
NAVI
CESR130227-xx-xx

Alarms and Alerts

There are a variety of different alerts and alarms in the system.
P — Pre-Alert: Part of the unit is temporarily down. The alarm is
not broadcast on the CCN network. The alarm relay is not ener-
gized. After an allowable number of retries, if the function does
not recover, the pre-alert will be upgraded to an alert or an alarm.
T — Alert: Part of the unit is down, but the unit is still partially
able to provide cooling or heating.
A — Alarm: The unit is down and is unable to provide cooling or
heating.
All alarms are displayed with a code of AXXX where the A is the
category of alarm (Pre-Alert, Alert, or Alarm) and XXX is the
number.
The response of the control system to various alerts and alarms de-
pends on the seriousness of the particular alert or alarm. In the
mildest case, an alert does not affect the operation of the unit in
any manner. An alert can also cause a "strike." A "striking" alert
will cause the circuit to shut down for 15 minutes. This feature re-
duces the likelihood of false alarms causing a properly working
system to be shut down incorrectly. If three strikes occur before
the circuit has an opportunity to show that it can function properly,
the circuit will strike out, causing the shutdown alarm for that par-
ticular circuit. Once activated, the shutdown alarm can only be
cleared via an alarm reset.
Table 103 — Compressor Run Hours Display Table
EXPANSION
Table 104 — Compressor Starts Display Table
EXPANSION
Table 105 — Software Version Numbers Display Table
EXPANSION
RANGE
UNITS
0-999999
HRS
0-999999
HRS
0-999999
HRS
0-999999
HRS
0-999999
HRS
0-999999
HRS
RANGE
UNITS
0-999999
0-999999
0-999999
0-999999
0-999999
0-999999
RANGE
UNITS
Circuits with strikes are given an opportunity to reset their strike
counter to zero. As discussed above, a strike typically causes the
circuit to shut down. Fifteen minutes later, that circuit will once
again be allowed to run. If the circuit is able to run for 1 minute, its
replacement circuit will be allowed to shut down (if not required
to run to satisfy requested stages). However, the "troubled" circuit
must run continuously for 5 minutes with no detectable problems
before the strike counter is reset to zero.
In addition, the compressors have several diagnostics monitoring
the safety of the system which may cause a number of attempts to
be re-tried before locking out the system from operation. This fea-
ture reduces the likelihood of false alarms causing a properly
working system to be shut down incorrectly.
For the compressor and circuit diagnostics, some of these alerts/
alarms will not broadcast an initial failure to the CCN network un-
til all attempts to recover have occurred and failed. These alerts
will be accessible in the alarm history of the control
(Alarms
HIST).
All the alarms and alerts are summarized in Table 106.
122
CCN POINT
HOURS_A1
config
HOURS_A2
config
HOURS_A3
config
HOURS_B1
config
HOURS_B2
config
HOURS_B3
config
CCN POINT
CY_A1
config
CY_A2
config
CY_A3
config
CY_B1
config
CY_B2
config
CY_B3
config
CCN POINT
string
string
string
string
string
string
string
string
string
string
DEFAULT