MCi Crusader II 1989 Maintenance Manual page 488

Advertisement

Date
1-1-89
Page
16-18
MC-9 MAINTENANCE MANUAL·
9. Subtract the average equivalent temperature (from
step 6) from the average remote bulb temperature (from
step 7). Example:
Avg Temp. at Bulb: 49°F (10°C)
SubtractAvgEquiv.Temp.atFitting:
-41°F ( 5.25°C)
Difference:
8°F ( 4.75°C)
The difference in the average temperatures should be
from 10-12°F (5-6°C). lfmorethan 12°F (6°C) or less than
10°F (5°C), as in the example, the expansion valve
requires adjustment (see step 10) and the entire proce-
dure should be repeated.
CAUTION: Before adjusting the expan-
sion valve, check for a restricted suction
llne, plugged fllter dryer or for a partially
opened valve.
To verify the need for expansion valve adjustment perform
steps 10-17.
10. Remove the gauges from the expansion valve and
install them at the compressor gauge connections; pres-
sure gauge in suction lineandtemperaturegaugeinstalled
to indicate suction line temperature.
11. Run the system for 10 minutes, set at 82°F (28°C).
12. Measure and record the line pressure and temperture.
13. Determine equivalent temperature from the chart.
Example: 30 psi (206 kPa) equals 32°F (0°C).
14. Subtract the equivalent temperature from the line
temperature indicated on the tern perature gauge. Example:
Temperature Gauge Reading: 40°F (4°C)
Subtract Equivalent Temperature:
-32°F (0°C)
Answer:
8°F (4°C)
15. The answer represents the indicated superheat. If
this temperature is approximately equal to the superheat
temperature determined in step 8, above, there is no appar-
ent restriction in the suction line or filter dryer, nor an open
valve. Proceed to step 17.
16. If the answer (step 14) is not approximately equal to
the superheat temperature determined in step 8, determine
the cause of the different readings (e.g. suction line restric-
tion, clogged futer dryer or malfunctioning valve) and
repair the defective part. Repeat steps 1-16 to determine
need for expansion valve adjustment.
17. To adjust the superheat setting on the expansion
valve, turn the adjustment screw clockwise to increase
superheat temperature, counterclockwise to lower super-
heat temperature.
18. Repeat steps 2 thru 9 to verify correct valve setting.
MAINTENANCE-
1. Pump down the system as directed earlier in this
section.
2. See figures 16-19 and 16-20. At ttie expansion valve,
disconnect the external equalizer line from the underside of
the power head and unclamp the remote control bulb from
the evaporator coil outlet line.
PRESSURES AND EQUIVALENT TEMPERATURES (FREON 12)
STANDARD UNITS
METRIC UNITS
STANDARD UNITS
METRIC UNITS
PSI
OF
KPA
oc
PSI
OF
KPA
oc
25
28
171
-2
48
51
329
11
26
29
178
-2
49
52
336
11
27
30
185
-1
50
53
343
12
28
31
192
-1
51
54
349
12
29
32
199
0
52
55
356
12
30
33
206
1
53
56
363
13
31
34
212
1
54
57
370
13
32
35
219
2
55
58
377
14
33
36
226
2
56
59
384
14
34
37
233
3
57
60
390
15
35
38
240
3
58
60
397
16
36
39
247
4
59
61
404
16
37
40
253
4
60
62
411
16
38
41
266
5
61
63
418
17
39
42
267
6
62
64
425
17
40
43
275
6
63
64
432
18
41
44
281
7
64
65
438
18
42
45
288
7
65
66
445
18
43
46
295
8
66
67
452
19
44
47
301
8
67
68
459
19
45
48
308
9
68
68
466
20
46
.
49
315
9
69
69
473
21
47
50
322
10
70
70
480
21

Hide quick links:

Advertisement

loading

Related Products for MCi Crusader II 1989

This manual is also suitable for:

Mc-9 1989