Download Print this page

MCi Crusader II 1989 Maintenance Manual page 356

Advertisement

Date
1-1-89
Page
.---11_-_1s _ _
MC-9 MAINTENANCE MANUAL
Figure 11-36. Removing the Rack Piston.
35. Placf!! the rack piston worm shaft assembly on a clean
cloth to prevent the piston from rolling.
36. Remove the two Allen head bolts (4d) (Figure 11-37)
from the ball return guide cap (4e): remove the ball return
guide cap (Figure 11-38) and the ball return guide cap seal (4t).
Figure 11-37. Allen Head Bolt Removal •
.
~
.
·:.;~
Figure 11-38. Removing Guide Cap.
37. Remove the two ball return guides (4c or 4g) (figure
11-39) and the balls (18) from the rack piston (10) by rotating
the worm sha~ (5a) until the balls tall out (figure 11-40).
NOTE: Ball return guides are closely fitted
with the rack piston and you may have to
remove them by carefully inserting a screw-
driver between the rack piston and ball
return guides.
CAUTION: Assembly contains a set of 34
matched balls, and you must take special
care not to lose any. If any balls are lost, a
complete, new set of matched balls will be
required.
·
Figure 11-39. Loosening Ball Return Guides.
Figure 11-40. Removal of Balls.

Hide quick links:

Advertisement

loading

Related Products for MCi Crusader II 1989

This manual is also suitable for:

Mc-9 1989