3. PERIODIC CHECK
[2]
3.15.2

Replacing the fusing claw assy

A. Periodically replaced part/cycle
Fusing claw assy: Every 500,000 prints
B. Procedure
[1]
78
[1]
50gaf2c087na
[2]
50gaf2c088na
[1]
50gaf2c089na
Field Service Ver1.0 Feb.2006
9.
Remove the 2 screws [1] and then remove the
fusing unit [2].
Note
• When lifting the fusing unit, be sure to hold it
at both ends.
• When installing/removing it, be careful not to
damage rollers.
10.
Reinstall the above parts following the removal
steps in reverse.
1.
Remove the fusing unit.
(See P.76)
2.
Remove the C-clip [1].
3.
Open the fusing front guide assy [2].
4.
Slide the fusing front guide assy [1] for removal.

Advertisement