Field Service Ver. 1.0 Feb. 2006
ADJUSTMENT/SETTING
4.
MECHANICAL ADJUSTMENT
4.1
Staple Position Adjustment
B
C
D
A
B
C
D
E
F
[1]
A
[2]
[3]
4349f3c001na
4. MECHANICAL ADJUSTMENT
1. Set the staple and make a print.
2. Check the staple position of the paper.
• Slant one point Staple [1]
(Paper Width: 216 to 297 mm)
279 to 297 mm: 45°,
B5, B4: 30°
Measurement
Specification
position
A, C
4.4 mm
B, D
12.1 mm
• Parallel one point Staple [2]
(Paper Width: 182 to 216 mm)
Measurement
Specification
position
A
4.5 mm
B
6 mm
• Parallel two points Staple [3]
Measurement
Specification
position
C, F
6 mm
D
Y
E
X
Y = (paper width–X–11) / 2
X = A3, A4: 137 mm
B4, B5: 114 mm
A4S: 190 mm
B5S: 162 mm
1
11 x 17, 8
/
x 11: 119.4 mm
2
8
1
/
x 11S: 196 mm
2
Substitute above into the equation.
3. If the staple position is misaligned,
adjust with the following procedure.
Adjustment
range
—
+1 to –2mm
Adjustment
range
—
+1 to –2mm
Adjustment
range
+1 to –2mm
—
—
21