Field Service Ver1.0 Feb.2006
3.5

Maintenance procedure of the external section

3.5.1

Replacing the ozone filter

A. Periodically replaced part/cycle
Ozone filter: Every 250,000 prints
B. Procedure
[1]
[2]
1.
Remove the right cover /Up.
(See P.122)
2.
Remove the ozone filter [1].
Note
• When removing the ozone filter, be sure to
pull it out by holding it at the section indicated
by [2].
3.
Reinstall the above parts following the removal
steps in reverse.
50gaf2c014na