Konica Minolta bizhub 500 Service Manual page 794

Hide thumbs Also See for bizhub 500:
Table of Contents

Advertisement

Field Service Ver. 1.0 Feb. 2006
[20]
[22]
[24]
[28]
[29]
[21]
[20]
4061f2c232na
[23]
[22]
4061f2c233na
[27]
[25]
[26]
[24]
4061f2c234na
[29]
[28]
[30]
4061f2c235na
13. Remove four screws [20] and remove
the Side Guide Assy /Rr [21].
14. Remove four screws [22] and remove
the Side Guide Assy /Fr [23].
15. Remove three C-rings [24], the bearing
[25], and two gears [26].
16. Remove the Wire Pulley Assy [27].
17. Remove two C-rings [28] and the Wire
Pulley [29].
NOTE
• Take care not to lose fixing pins.
• When reinstalling the Wire Pulley,
check that the direction of the wire
coming from both wire pulleys are the
same.
• Install so that cut parts [30] at both
ends of shaft face up.
3. OTHER