10. SERVICE MODE
(6) Response Time Out
Functions
Use
• Not Used. (To be used when connected by E-mail.)
Setting/
Procedure
D. AT Command
Functions
• To set the command to be issued at the time of Modem Initialization.
• This setting is available only when [Modem] is selected for the system setting.
Use
• To set the command to be issued at the time of Modem Initialization.
Setting/
• Enter the command and touch [SET] to register.
Procedure
E. Server set
Functions
Use
• Not Used.
Setting/
Procedure
10.11.9 List of the CS Remote Care error code
Note
• Error codes in the shaded region may occur when transmitting from the machine to the center.
Error code
0001
The line is busy (Busy detection)
0002
Failure of the Modem default setting at transmitting
(When the transmission completes with modem ini-
tial setting failed)
0003
Timeout of CONNECT at transmitting
(No response to ATD)
0004
Timeout of Incoming request response
(No response to incoming (starting) request MSG)
234
Error
Field Service Ver1.0 Feb.2006
Solution
• Transmit again manually.
• Check if the power of the modem
is ON.
• Check the connecting condition
between the modem and the
main unit.
• Transmit again manually
• Check if the power of the modem
is ON.
• Check the connecting condition
between the modem and the
main unit.
• Contact responsible person of
KONICA MINOLTA.