3. PERIODIC CHECK
3.10.2
Replacing the suction cover /2 assy
A. Periodically replaced part/cycle
•
Suction cover /2 assy: Every 250,000 prints
B. Procedure
[3]
40
[2]
[1]
50gaf2c044na
Field Service Ver1.0 Feb.2006
1.
Remove the developing unit from the main body.
(See P.35)
2.
Open ADU.
(See P.122)
3.
Open the conveyance unit.
(See P.27)
4.
Remove the drum unit from the main body.
(See P.27)
5.
Remove the screw [1] and then remove the rail [2].
Note
• When installing the rail, be sure first to insert
the tip into the notch [3].