Field Service Ver. 1.0 Jun. 2008
3.4

Maintenance procedure (periodical check parts)

NOTE
• The alcohol described in the cleaning procedure of maintenance represents the
isopropyl alcohol.
3.4.1

Cleaning of the timing roller

A. Periodically cleaning parts/cycle
• Timing roller: Every 60,000 prints (upon each call)
B. Procedure
1. Open the right door.
[1]
3.4.2

Cleaning of the area around the waste toner collecting port

A. Periodically cleaning parts/cycle
• Area around the waste toner collecting port: Every 60,000 prints (upon each call)
B. Procedure
1. Remove the waste toner box.
See P.16
2. Using a cleaning pad with alcohol,
wipe the timing roller [1] clean of dirt.
A02FF2C001DA
2. Wipe the areas around the waste
toner collecting port clean of spilled
toner and dirt using a cleaning pad
with water or alcohol.
A02FF2C002DA
3. Periodical check
15