Field Service Ver. 4.0 Feb. 2006
3.4

Maintenance procedure (Periodic parts check)

NOTE
• The alcohol referred to in the following procedures is isopropyl alcohol.
3.4.1

Pick-up Roller

[1]
A. Cleaning Procedure
1. Open the Top Cover.
2. Remove the Drum Cartridge.
☞ 17
NOTE
• Position the removed drum car-
tridge as shown in the illustration at
the left.
• Be sure to keep the drum cartridge
horizontal and place it where it will
not become dirty.
• Do not leave the drum cartridge
4139fs2538c0
removed for more than 15 minutes,
and do not place the removed drum
cartridge in a location where it will
be exposed to direct light (such as
sunlight).
3. Using a soft cloth dampened with
[1]
alcohol, wipe the Pick-up Roller [1]
clean of dirt.
4139fs2501c0
3. Periodic check