Rotating Diffuser Assembly - Christie CineLife+ CP4415-RGB Service Manual

Hide thumbs Also See for CineLife+ CP4415-RGB:
Table of Contents

Advertisement

2. Remove the electronics-side cover (on page 46).
3. Remove the front cover (on page 47).
4. Unlock the service door and open the door.
5. Release the light engine coolant lines from the clips.
6. Loosen the screw on the light engine coolant hose guard.
7. Disconnect the light engine coolant hoses.
8. Loosen two screws on the coolant hose front plate.
9. Remove the four screws securing the fold mirror housing.
10. Remove the fold mirror adjustment assembly and replace.
11. To re-install, follow these steps in reverse order.
12. After the re-installation, follow the instructions in Adjusting the integrator rod and fold mirror
(on page 20).

Rotating diffuser assembly

Learn how to remove the rotating diffuser.
1. Remove the electronics side cover (on page 46).
2. Remove the card cage (on page 78).
3. Loosen the six screws securing the rotating diffuser cover.
CineLife+ 4K-RGB Service Guide–CP4415-RGB, CP4420-RGB, CP4425-RGB, CP4435-RGB
020-103257-02 Rev. 1 (08-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Optics
98