Adjusting The Rod Assembly - Christie GS Series Service Manual

Hide thumbs Also See for GS Series:
Table of Contents

Advertisement

ID
Part name
3
Test pattern
4
Inspection items
1.On the IR remote keypad, press Menu > Size & Position > Size Presets > Full Size.
2.Enter Factory mode.
See
Entering Factory mode
3.Select ADC Calibration > Help.
After a few seconds, the ADC calibration status changes from Doing to Done.

Adjusting the ROD assembly

Avoid over-adjusting the ROD to prevent damage.
Warning! If not avoided, the following could result in death or serious injury.
• This projector has built-in Class 4 laser module. Never attempt to operate the projector without all
covers properly installed unless instructed to do so in this manual for service.
• Do not look into the projector lens when the laser is on. The extremely high brightness can cause
permanent eye damage.
1.Remove the top cover.
See
Removing the top cover
2.To power on with the top cover removed, firmly hold the interlock switch on the left-side cover.
3.Project an image of 100 inches in a dark environment (< 2 Lux).
4.Enter Service mode.
See
Entering Service mode
5.Click Test Pattern, select the White Screen test pattern.
GS Series 1075 Service Manual
020-001236-02 Rev. 1 (12-2019)
Description
SMPTE BAR
Check if the ADC calibration status has changed from Doing to Done.
on page 18.
on page 63.
on page 18.
Service setups
24

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dhd1075-gsDwu1075-gs

Table of Contents