5. Remove the integrator assembly (on page 92).
6. Remove the four screws securing the coupling elbow to the base plate.
7. Install the new coupling elbow on the integrator assembly.
8. To re-install these components (except the top and electronics-side covers), follow these steps
in reverse order.
Ensure the card cage and top cover locking pins are engaged when re-installing.
The electronics-side cover must be removed for making LOS coupling mirror adjustments. For
more information, refer to Aligning the image (on page 32).
9. Perform a LiteLOC calibration (on page 27).
Coupling elbow mirror
Learn how to replace the coupling elbow mirror.
1. Remove the card cage (on page 78)
2. Remove the screws securing the mirror.
CineLife+ 4K-RGB Service Guide–CP4415-RGB, CP4420-RGB, CP4425-RGB, CP4435-RGB
020-103257-02 Rev. 1 (08-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Optics
101