Power supplies for CP4425-RGB and CP4435-
RGB
The CineLife+ 4K-RGB power supply assembly includes individual 12V and 48V power supply modules
secured within a support bracket.
Only applies to: CP4425-RGB and CP4435-RGB
The 12V power supply module provides the required voltages for operating the electronics in the
projector and for receiving a UPS connection (if installed).
The 48V power supply module provides the required voltages for the lasers and pumps.
Before servicing, always carefully observe the original lead dress. Take extra precautions to secure all
harnessing properly, especially in the high voltage circuitry areas. Replace any wire that appears to
have damaged insulation.
1. Shut down the projector and ensure it is disconnected from AC.
2. Remove the rear cover (on page 45).
3. Disconnect the three-pin MAIN or UPS inline connector (whichever is already connected) from
the 12V power supply module.
4. Disconnect the 4-pin unmarked inline connector from the 48V power supply module.
5. For CP4425-RGB and CP4435-RGB, disconnect the following:
12V LVPS (Comm) harness from the 12V power supply
Two DC output cables from the 12V power supply
CN2 (Comm) harness connector from the 48V power supply
Two DC output cables from the 48V power supply
6. Loosen the three screws securing the power supply module to the projector system.
CineLife+ 4K-RGB Service Guide–CP4415-RGB, CP4420-RGB, CP4425-RGB, CP4435-RGB
020-103257-02 Rev. 1 (08-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Electronics
85