When correctly oriented in the projector, the 12V power supply is located at the top of the
assembly with the 48V beneath it, with the handle and support brackets fitting over the three
locating pins.
Laser driver card cage for CP4415-RGB and
CP4420-RGB
The laser drive card cage powers the lasers and contains the CS18G6 board.
Only applies to: CP4415-RGB and CP4420-RGB
1. Remove the radiator intake fans for CP4415-RGB and CP4420-RGB (on page 58).
2. Disconnect the harness connectors J172, J113, J111, J164, J128, J171, and J170.
3. Loosen the four screws securing the laser driver DCC module to the projector frame.
4. Using the metal flanges provided, pull the laser driver card cage out of the projector.
CineLife+ 4K-RGB Service Guide–CP4415-RGB, CP4420-RGB, CP4425-RGB, CP4435-RGB
020-103257-02 Rev. 1 (08-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.