2. Remove the side-intake cover (on page 47).
3. Remove the air filter.
4. Disconnect the harness from the back of the unit.
To unlock the connector, push up on the tab at the bottom-center of the connector nearest the
wires.
5. Place cloth wipes around the cooling hose connection points to capture any excess coolant that
may drip upon disconnect.
6. Disconnect the laser optical subsystem (LOS) coolant connector and the two light engine
coolant connectors.
7. Free the hoses from their clips.
8. Loosen the two screws and remove the two radiator handles from the back of the projector.
9. Slide the handles into the top of the radiator assembly and tighten the screws to attach the
handles to the radiator assembly.