The lens cap minimizes any stray light entering through the lens and maximizes darkness
around the sensor during the calibration.
2. Enable direct communication to photon controller.
a) Set the IP address of the projector and the IP address of the laptop to be on the same
subnet.
This connection can be a direct connection to the management port on the FMAIN through
wired/wireless network.
b) Connect the laptop to the projector using Net Terminal or Kore Librarian, with port 5000.
c) Log in as the Service account.
d) To enable the communication to the photon controller, send the command (CAL+PASS 1).
3. Connect the laptop to the photon controller using Net Terminal or Kore Librarian, with port
5103.
4. To start the DAC calibration, send the following command: (ENG+CALB 0 0).
This process takes approximately one minute. The system displays information on the start
and finish of the calibration process. DAC calibration is only required after replacing the color
sensor board.
5. Remove the lens cap.
6. To complete the calibration, power cycle the projector.
7. Proceed to the instructions in Calibrating LiteLOC.