10. To set the convergence for that corner of the screen, select Apply.
11. Repeat steps 7 to 10 for the remaining corners.
12. If necessary, reset the correction back to zero (no correction) or the previously saved
correction by selecting Reset.
In the Reset dialog, reset the current corner or all four corners. When the locations and value
are set, select Reset.
13. To save the current ECC settings, when the convergence is complete, select Save beside the
ILS file named at the top of the panel.
LiteLOC
sensor-to-screen calibration
The LiteLOC sensor-to-screen calibration is performed in the factory under specific setup conditions
which include the type of lens, screen, and the spectroradiometer used for measuring screen color and
brightness.
Your projector's setup conditions may not match the factory setup which may result in an discrepancy
in color accuracy. Upon first installation, check the accuracy of the color point and if unsatisfactory,
perform this calibration. Doing this calibration captures all the variables of your setup and achieves the
CineLife+ 4K-RGB Service Guide–CP4415-RGB, CP4420-RGB, CP4425-RGB, CP4435-RGB