Snood (Integrator); Integrator Assembly - Christie CP4230 Service Manual

Hide thumbs Also See for CP4230:
Table of Contents

Advertisement

Section 5: Parts and Module Replacement

5.8.4 Snood (Integrator)

The snood is located before the integrator and is removed when the Dolby
(Estimated Replacement Time: 2 minutes)
1. Remove the front top lid. Refer to
2. Remove the hex screw securing the snood. (Figure 5-27)
3. Remove the snood.

5.8.5 Integrator Assembly

and should not be worn when performing this step.
(Estimated Replacement Time: 12 minutes + 15 minute calibration)
The integrator assembly is positioned on the IOS.
1. Remove the front top lid. Refer to
5-6.
2. Remove the two, 3mm hex screws securing the retaining clip to
the rear end of the integrator. (Figure 5-28)
NOTICE! Perform this step with caution to avoid
damaging the temperature sensor mounted nearby.
3. Remove the snood. Refer to
5-20.
4. Wearing the gloves provided with the Service Kit, carefully
remove the integrator assembly and set aside in a clean area
where it cannot be damaged.
5. When re-installing, repeat instructions in reverse. After
powering up the projector, adjust the integrator and fold mirror
as required for proper aperture alignment. For details, refer to
Section 3 Service
5-20
5.4.2 Front Top Lid, on page 5-6.
Wear the gloves provided in the Service Kit whenever handling the integrator.
The gloves do not provide heat protection when adjusting the integrator rod
5.4.2 Front Top Lid, on page
5.8.4 Snood (Integrator), on page
Setups.
filter wheel is used.
®
Figure 5-27 Screw
Securing Snood
Figure 5-28 Integrator Assembly
CP4230 Service Manual
020-100622-04 Rev. 1 (05-2016)