7. Slide the power supply assembly over the rails and out of the projector, and set it on a clean,
level surface.
8. Remove the two screws securing the handle bracket to the power supply assembly.
9. Remove the eight screws securing the support bracket around the power supply assembly.
10. Remove the affected power supply module.
11. Replace it with the new power supply module.
12. To re-install, follow these steps in reverse order.
When reconnecting the DC outputs, make sure all positive and negative terminal connections
are torqued to 30 in-lb.