4. Remove the aluminum bracket that covers the hoses at the front behind the inside the
projector and remove the hoses from their clamps.
5. Disconnect the pump module coolant connectors (LOS line and light engine line).
6. Disconnect the power-harness connector.
7. Loosen the two screws to release the pump.
CineLife+ 4K-RGB Service Guide–CP4415-RGB, CP4420-RGB, CP4425-RGB, CP4435-RGB
020-103257-02 Rev. 1 (08-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Ventilation and cooling
76