Christie CineLife+ 4 Series Technical Reference

Christie CineLife+ 4 Series Technical Reference

Serial commands
Hide thumbs Also See for CineLife+ 4 Series:

Advertisement

Quick Links

Technical Reference
020-103075-05
CineLife+
Serial Commands

Advertisement

Table of Contents
loading

Summary of Contents for Christie CineLife+ 4 Series

  • Page 1 Technical Reference 020-103075-05 CineLife+ Serial Commands...
  • Page 2 Christie's control such as maintenance of the product in proper working conditions. Performance specifications are based on information available at the time of printing. Christie makes no warranty of any kind with regard to this material, including, but not limited to, implied warranties of fitness for a particular purpose.
  • Page 3: Table Of Contents

    ZOM–Lens Zoom Position Adjustment........30 CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 4: Communicating With The Projector

    CP2420-Xe • CP4420-Xe Product documentation For installation, setup, and user information, see the product documentation available on the Christie website. Read all instructions before using or servicing this product. 1. Access the documentation from the Christie website: • Go to this URL: https://bit.ly/3lkZ48l or https://www.christiedigital.com/products/projectors/cinema-projectors/.
  • Page 5: Connecting To The Projector Ethernet Port

    Generally, Set and Reply messages have the same data in the same format, and Requests do not contain any data. CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 6: Basic Message Structure

    If the controller is requesting information from CineLife+, a question mark (?) appears directly after the function code. If CineLife+ is replying, an exclamation CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 7: Special Characters For Text

    Send arbitrary code \h## Sends one arbitrary code defined by the two hexadecimal digits ##. CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 8: Confirming Command Execution

    For example, the following message indicates a syntax error: (65535 00000 ERR00005 "TMD+TIME: Too Few Parameters") CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 9: Cinelife+ ™ Serial Commands

    (AUT+EXEC "MyScript" "MyMacro1") Execute the MyMacro macro from the MyMacro script: (AUT+EXEC "MyMacro") CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 10: Cha-Channel

    Parameters • Access level: Operator • Power level (minimum): Power Up CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 11: Gam-Gamma Control

    Gets or sets the gamma file, which describes the gamma response curve for the source signal. Parameters • Access level: Installer • Power level (minimum): Power Up CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 12 Set the gamma file for the specified channel to the specified file at index 1 from the previous listing: (GAM+CHAN "Media Block Flat" 1) CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 13: Hlp-Serial Help

    Returns the ILS file used by the specified channel = Name of a valid channel "<channel>" channel. (Read-only) CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 14: Ils-Ils Setup

    Returns the status of the calibration. (Read-only) — 0 = Completed. 1 = In progress. CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 15: Inr-Interrogator

    Power level (minimum): Power Up Commands Command Description Values INR 1 Initiates an interrogator. CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 16: Lho-Lens Horizontal Position Adjustment

    Starts the motor moving in a specified direction. -1 = Negative approach 1 = Positive approach CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 17: Lpf-Lamp File

    Sets the lamp file for the active channel. lamp file = Subject to the range returned in LPF? or LPF?L CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 18 (LPF!L001 001 002 "2270_80") (LPF!L001 001 003 "2270_90") (LPF!L001 001 004 "BHavana_temp") (LPF!L001 001 005 "Bhavana_Laser_File") CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 19: Lpm-Lamp Mode

    ILS File Setup panel of the user interface, the selected lens file becomes active. This file may be different from the one specified by the current channel. CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 20 Stop the motor: (LVO+STOP) Start the motor moving in a positive direction: (LVO+STRT 1) CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 21: Mcg-Measured Color Gamut

    Examples Return the active MCGD file: (MCG?) CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 22: Msg-User Message

    The message on the graphical user interface appears in a popup window, which the operator can acknowledge. Parameters • Access level: Operator CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 23: Png-Ping

    • <beta> = Indicates it is an engineering build and has not been validated PNG+BILD Returns the package version (build number). — CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 24: Pwr-Power

    Return the target power state from the latest command sent to the projector: (PWR?) CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 25: Shu-Shutter

    Indicates the shutter is open. Open the shutter: (SHU 0) Close the shutter: (SHU 1) CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 26: Sst-System Status

    Returns version numbers. (Read-only) SST+VIDO? Returns video related data. (Read-only) Examples Return the projector status: (SST+ALRM?) CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 27: Tcg-Target Color Gamut

    Set the TCGD file of the active channel to index 1 from a previous listing: (TCG 1) CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 28: Tmd-Time And Date

    Return the status of Daylight Saving Time: (TMD+DSTA?) Disable Daylight Saving Time: (TMD+DSTA 0) CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 29: Uid-User Id

    Logs out the current user. This also happens when a new user logs — CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 30: Zom-Lens Zoom Position Adjustment

    (ZOM 500 1) Move Zoom to position 500 with a negative approach: (ZOM 500 -1) CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 31 Stop the motor: (ZOM+STOP) Start the motor moving in a positive direction: (ZOM+STRT 1) CineLife+ Technical Reference–Serial Commands 020-103075-05 Rev. 1 (09-2022) Copyright © 2022 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.

This manual is also suitable for:

Cp2415-xeCp2420-xeCp4420-xeCp4415-rgb

Table of Contents