To Run The Move Cartridge Test - Sun Microsystems SPARCstorage Library Service Manual

Hide thumbs Also See for SPARCstorage Library:
Table of Contents

Advertisement

2
2-32

To run the Move Cartridge test

The Move Cartridge test picks a cartridge from one element index and moves
it to another.
Note – If you insert a cartridge into a tape drive, the drive does not
automatically eject the cartridge.
The system displays an error message if there is no cartridge in the source
element slot or if the destination element slot is full. Select another element
address. See Figure 2-4 on page 2-27.
1. Disable security (the display panel reads Set Security On when security is
disabled).
If the display panel reads Set Security Off, security is turned on. See "To
enable or disable security" on page 2-22.
2. Put the tape library into LCD Interface mode:
a. Press Escape until the primary menu is displayed.
b. Select the Interface Menu by pressing
c. Select the Control Mode Menu by pressing
d. Select LCD Interface mode by pressing
3. Select the Maintenance Menu by pressing
4. Select the Diagnostics Menu by pressing
5. Select Move Cartridge by pressing
The system displays the following screen:
Set Source
↑ Increase
↓ Decrease
SPARCstorage Library Service Manual—June 1995
or
, then Enter.
or
, then Enter.
or
, then Enter.
or
, then Enter.
or
, then Enter.
or
, then Enter.
0