2
2-28
The following chart describes the diagnostics available and a brief description
of each diagnostic.
Self Test
Position to Elem
Park
Move Cartridge
Scan
Scan with Range
Home Gripper
Home CHM
Cycle Pick/Place
SPARCstorage Library Service Manual—June 1995
Performs the following tests:
- Performs a Home CHM test
- Cycles the CHM along the short axis once
- Cycles the CHM along the long axis once
- Moves the CHM to the home position
Moves the CHM to one of the tape drives or to one of the
cartridge slots. You must specify an element address for
the destination. See Figure 2-4 on page 2-27.
Moves the CHM to the park position
(to the right of the cartridge magazine in the tabletop
and rack-mounted units or at the top in the tower unit).
Moves a cartridge from one location to another. You
must specify an element address for the source and
destination. See Figure 2-4 on page 2-27.
Scans the element where the bar code scanner is
currently located.
Scans a range of elements.
Causes the gripper to move to the home position (open).
Causes the CHM to:
- Retract on its short axis
- Move to the top of the long axis (tower unit) or to the
right (tabletop and rack-mounted units)
- Move in front of the tape drives, then open and close its
gripper.
Causes the CHM to take a cartridge from a specified slot
or CTS and replace it in the same slot. You must specify
the source slot (see Figure 2-4 on page 2-27) and the
number of pick/place cycles that the CHM should
perform in increments of 10 (up to 250).