D-4
Table D-2 Hardware Error Sense Key (4h) ASC and ASCQ Values (Continued)
ASCQ
Display
Byte 13
Panel
Number
89h
77
90h
20
91h
21
92h
22
A0h
30
A2h
32
A3h
36
A4h
37
A5h
73
B0h
40
B1h
41
B2h
42
B3h
46
B4h
47
B5h
70
E4h
99
SPARCstorage Library Service Manual—June 1995
Description
The tape library was not in the correct control mode when
the command was executed.
To invoke commands from the Maintenance Menu, the
tape library must be in LCD Interface mode.
To run the SunDiag system exerciser, the tape library must
be in one of the Sequential modes (Sequential CTS1,
Sequential CTS2, or Dual Sequential).
Under normal operation, the tape library must be set to
SCSI Interface mode.
The gripper home sensor did not clear.
A gripper error occurred.
A gripper motion took longer than the maximum time
allocated for it. When motion functions do not complete in
the allocated time, current to the servo motors is cut off.
The CHM could not move along the short axis.
The motor on the short axis failed.
The tape library could not reset the servo chip for the short
axis.
The servo busy bit on the short axis failed.
The CHM could not reach its destination on the short axis.
The CHM could not move on the long axis.
The CHM could not return to home position on the long
axis.
The motor on the long axis failed.
The tape library could not reset the servo chip for the long
axis.
The servo busy bit on the long axis failed.
The CHM could not reach its destination on the long axis.
One of the motors is stalled. The tape library must wait
for it to cool down before operations can resume.