To Check Or Set The Scsi Mode Parameters - Sun Microsystems SPARCstorage Library Service Manual

Hide thumbs Also See for SPARCstorage Library:
Table of Contents

Advertisement

2
2-42

To check or set the SCSI Mode Parameters

1. Select the Library Info Menu by pressing
2. Select the SCSI Menu by pressing
3. Select SCSI Mode Parameters by pressing
4. Check the settings of the various operating mode parameters. Scroll up
by pressing
or scroll down by pressing
The SCSI mode parameters screen provides the current (Cur), default (Def),
and saved (Sav) values for the following parameters.
Current (Cur)
Default (Def)
Saved (Sav)
The mode parameters for this menu are:
CHM Addr
Stor Addr
CTS Addr
CTS Num
SPARCstorage Library Service Manual—June 1995
or
or
, then Enter.
or
.
The value currently active (either the power-on default
or a temporary value set by the latest MODE SELECT
command.
The original value set at the factory.
The value specified as the power-on default by a MODE
SELECT command. After specifying a value with the
MODE SELECT command, this value takes effect each
time you power on the tape library.
The element address of the cartridge handling
mechanism.
The element address of the fixed slot. The remaining
cartridge slots are numbered consecutively—starting
from the topmost slot (for the tower unit) or the
rightmost slot (for the tabletop and rack-mounted units).
The element address of the first cartridge tape subsystem
(CTS). The remaining CTS is numbered sequentially.
The number of CTSs installed.
, then Enter.
, then Enter.