2.3.4.3 System Sensors

The System Sensors display lets you check the current status of the internal
mechanical sensors.

To check the status of the sensors

1. Select the Library Info Menu by pressing
2. Select System Sensors by pressing
The system displays the Digital Sensors screen followed by the Analog
Sensors screen. Use
DIGITAL SENSORS
Door Closed
Key Lock
Gripper Home
ANALOG SENSORS
Temperature:
+12V:
-12V:
Digital System Sensors
Table 2-6 lists the digital system sensor descriptions.
Table 2-6
Digital System Sensor Descriptions
Sensor
Door Closed
Key lock
Gripper Home
Cart seated
Vertical Mode
Troubleshooting
and
to scroll though the screens:
1
1
0 ↓
23C
11816 mV
12233 mV
Sensor Position 1
Door is closed.
Door locked.
Gripper is located in the
home position.
Cartridge is correctly seated
in the CHM.
Tabletop and rack-mounted
units
or
, then Enter.
or
, then Enter.
Sensor Position 0
Door is open.
Door is unlocked.
Gripper is not located in the
home position.
Cartridge is not correctly
seated in the CHM.
Tower unit.