Sun Microsystems SPARCstorage Library Service Manual page 96

Hide thumbs Also See for SPARCstorage Library:
Table of Contents

Advertisement

3
3.2 Diagnostics Menu
3-2
3. Press Escape until the primary menu is displayed.
See Figure 2-1 on page 2-10.
4. Select the Interface Menu by pressing
5. Select the Control Mode Menu by pressing
6. Select Sequential CTS1 (Cartridge Tape Subsystem 1), Sequential CTS2
(Cartridge Tape Subsystem 2), or Dual Sequential (for two drive models)
mode by pressing ↓, then Enter.
7. Set the Restart and Loop options to ON by pressing → or ←.
See "To set the restart option" on page 2-19 and "To set the loop option" on
page 2-20. The restart and loop options are under the Sequential Options
menu which is under the Configuration Menu.
→ Loop:
Restart:
8. Open and close the door of the tape library.
This action causes the unit to inventory cartridge locations and places a tape
in the tape drive (each tape drive in Dual Sequential Mode).
9. Press Escape until you get to the primary menu.
10. Select Main Screen by pressing Enter.
Leave the unit in Main Screen mode for normal operation.
11. Start the SunDiag system exerciser.
See the SunDiag User's Guide for instructions on how to use SunDiag.
12. When you are finished running SunDiag, put the tape library in the
control mode it was in before (Control Mode Menu under the Interface
Menu).
SCSI control mode is the normal operation mode.
To run diagnostics, use the Diagnostics Menu. For procedures, see
Section 2.3.3.3, "Diagnostics Menu," on page 2-27."
SPARCstorage Library Service Manual—June 1995
or
, then Enter.
or
, then Enter.
ON
ON