To Run The Self Test - Sun Microsystems SPARCstorage Library Service Manual

Hide thumbs Also See for SPARCstorage Library:
Table of Contents

Advertisement

Cycle Gripper
Cycle S Axis
Cycle L Axis
Cycle Solenoid

To run the Self Test

The following actions occur during the Self Test diagnostic:
The gripper fingers of the CHM move to the home position.
The CHM cycles the long and short axes once, then moves to the home
position at the bottom of the long axis.
1. Disable security (the display panel reads Set Security On when security is
disabled).
If the display panel reads Set Security Off, security is turned on. See "To
enable or disable security" on page 2-22.
2. Put the tape library into LCD Interface mode:
a. Press Escape until the primary menu is displayed.
b. Select the Interface Menu by pressing
c. Select the Control Mode Menu by pressing
d. Select LCD Interface mode by pressing
3. Select the Maintenance Menu by pressing
Troubleshooting
Causes the gripper to open and close. You must specify
the number of cycles in increments of 10 (up to 250).
Causes the CHM to move end to end along the short axis
(the axis where the CHM moves in and out). You must
specify the number of cycles the CHM must perform in
increments of 10 (up to 250).
Causes the CHM to move end to end along the long axis
(the axis where the CHM moves left and right for the
tabletop and rack-mounted units or up and down for the
tower unit). You must specify the number of cycles the
CHM must perform in increments of 10 (up to 250).
Cycles the door solenoid, used to lock the front door.
You must specify the number of cycles the CHM must
perform in increments of 10 (up to 250).
or
or
or
2
, then Enter.
or
, then Enter.
, then Enter.
, then Enter.
2-29

Advertisement

Table of Contents
loading