Sun Microsystems StorEdge 6130 Manual
Sun Microsystems StorEdge 6130 Manual

Sun Microsystems StorEdge 6130 Manual

Cluster 3.0-3.1
Hide thumbs Also See for StorEdge 6130:

Advertisement

Quick Links

Sun Cluster 3.0-3.1 With Sun
StorEdge 6130 Array Manual
For Solaris OS
Sun Microsystems, Inc.
4150 Network Circle
Santa Clara, CA 95054
U.S.A.
Part No: 817–7899–14
June 2006, Revision A

Advertisement

Table of Contents
loading

Summary of Contents for Sun Microsystems StorEdge 6130

  • Page 1 Sun Cluster 3.0-3.1 With Sun StorEdge 6130 Array Manual For Solaris OS Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 817–7899–14 June 2006, Revision A...
  • Page 2 Etats-Unis et dans d’autres pays; elle est licenciée exclusivement par X/Open Company, Ltd. Sun, Sun Microsystems, le logo Sun, le logo Solaris, le logo Java Coffee Cup, docs.sun.com, Java et Solaris sont des marques de fabrique ou des marques déposées de Sun Microsystems, Inc.
  • Page 3: Table Of Contents

    Preface ................................5 Restrictions and Requirements ......................... 11 Requirements ..............................11 Restrictions ..............................11 Installing and Configuring a Sun StorEdge 6130 Array ................13 Installing Storage Arrays ..........................13 Storage Array Cabling Configurations ....................13 How to Install Storage Arrays in a New Cluster ................14 M Install and Cable the Hardware ....................15...
  • Page 4 Contents Index ................................31 Sun Cluster 3.0-3.1 With Sun StorEdge 6130 Array Manual • June 2006, Revision A...
  • Page 5: Preface

    Preface The Sun Cluster 3.0-3.1 With Sun StorEdge 6130 Array Manual provides procedures that are specific to a Sun StorEdge 6130 or Sun StorEdge 6140 array that is placed in a Sun Cluster environment. Use this manual with any version of Sun Cluster 3.0 or 3.1 software on SPARC® based clusters and on any supported version of Sun Cluster 3.1 software on x86 based clusters.
  • Page 6 How This Book Is Organized This book contains the following chapters: Chapter 1 lists limitations of your use of Sun StorEdge 6130 or Sun StorEdge 6140 storage arrays in a Sun Cluster environment. Chapter 2 discusses how to install Sun StorEdge 6130 or Sun StorEdge 6140 storage arrays and how to configure logical units on them.
  • Page 7 Sun StorEdge 6130 Array Getting Started Guide 817–0032 Sun StorEdge 6130 Array Site Preparation Guide 819–0033 Sun StorEdge 6130 Regulatory and Safety Compliance Manual 819–0035 Sun StorEdge 6130 Array Release Notes 819–0034 Sun StorEdge Expansion Cabinet Installation and Service Manual 805–3067...
  • Page 8 Reports which patches are installed prtdiag -v Displays system diagnostic information /usr/cluster/bin/scinstall -pv Displays Sun Cluster release and package version information Also have available the contents of the /var/adm/messages file. Sun Cluster 3.0-3.1 With Sun StorEdge 6130 Array Manual • June 2006, Revision A...
  • Page 9 Preface Documentation, Support, and Training The Sun web site provides information about the following additional resources: Documentation (http://www.sun.com/documentation/) Support (http://www.sun.com/support/) Training (http://www.sun.com/training/) Typographic Conventions The following table describes the typographic conventions that are used in this book. Typographic Conventions TABLE P–4 Typeface Meaning Example...
  • Page 10 Sun Microsystems offers training in many Sun technologies through a variety of instructor-led courses and self-paced courses. For information about the training courses that Sun offers and to enroll in a class, visit Sun Training at http://training.sun.com/. Sun Cluster 3.0-3.1 With Sun StorEdge 6130 Array Manual • June 2006, Revision A...
  • Page 11: Restrictions And Requirements

    C H A P T E R Restrictions and Requirements This chapter includes only restrictions and requirements that have a direct impact on the procedures in this book. For general support information, contact your Sun service provider. Requirements Storage devices that support logical unit number (LUN) masking must implement masking so that LUNs are not visible to the Sun StorEdge 6130 storage system.
  • Page 13: Installing And Configuring A Sun Storedge 6130 Array

    “Installing Storage Arrays” on page 13 “Configuring Storage Arrays” on page 17 For detailed information about storage array architecture, features, configuration utilities, and installation, see the Sun StorEdge 6130 Array Getting Started Guide. For a URL to this storage documentation, see “Related Documentation” on page...
  • Page 14: How To Install Storage Arrays In A New Cluster

    You have not installed the Sun Cluster software. Your cluster has not been established. You have enough host adapters to connect the nodes and the storage array to the service processor panel. Sun Cluster 3.0-3.1 With Sun StorEdge 6130 Array Manual • June 2006, Revision A...
  • Page 15: M Install And Cable The Hardware

    Install and Cable the Hardware Unpack, place, and level the storage array. For instructions, see the Sun StorEdge 6130 Array Getting Started Guide or the Sun StorEdge online documentation. For a list of array documentation, see Table P–2.
  • Page 16: M How To Add Storage Arrays To An Existing Cluster

    Ensure that you install the required Solaris patches for storage array support. Unpack, place, and level the storage array. For instructions, see the Sun StorEdge 6130 Array Getting Started Guide or the Sun StorEdge online documentation. For a list of array documentation, see Table P–2.
  • Page 17: Configuring Storage Arrays

    Configuring Storage Arrays Install the storage array. For instructions, see the Sun StorEdge 6130 Array Getting Started Guide or the Sun StorEdge online documentation. Power on the storage array and the nodes. For instructions, see the Sun StorEdge 6130 Array Getting Started Guide or the Sun StorEdge online documentation.
  • Page 18 For the procedure about how to configure Traffic Manager paths, see the Sun StorEdge Traffic Manager Installation and Configuration Guide. On one node that is connected to the storage device, use the format command to label the new logical volume. Sun Cluster 3.0-3.1 With Sun StorEdge 6130 Array Manual • June 2006, Revision A...
  • Page 19: M How To Remove A Logical Volume

    The logical volume and the path between the nodes and the storage device are both operational. Identify the logical volume that you are removing. Refer to your Solstice DiskSuite/Solaris Volume Manager or VERITAS Volume Manager documentation for more information. Chapter 2 • Installing and Configuring a Sun StorEdge 6130 Array...
  • Page 20 Determine the resource groups and device groups that are running on all nodes. Record this information because you use it in Step 13 of this procedure to return resource groups and device groups to these nodes. # scstat Sun Cluster 3.0-3.1 With Sun StorEdge 6130 Array Manual • June 2006, Revision A...
  • Page 21 For each additional node that is connected to the shared storage that hosted the logical volume, repeat Step 8 Step (Optional) Return the resource groups and device groups that you identified in Step 8 to all cluster nodes. Chapter 2 • Installing and Configuring a Sun StorEdge 6130 Array...
  • Page 23: Maintaining A Sun Storedge 6130 Array

    “How to Replace a Disk Drive” on page 29 For detailed information about storage array architecture, features, and configuration utilities, see the Sun StorEdge 6130 Array Getting Started Guide or the Sun StorEdge online documentation. FRUs That Do Not Require Sun Cluster Maintenance Procedures In general, the following is a list of administrative tasks that require no cluster-specific procedures.
  • Page 24: Maintaining Storage Arrays

    “How to Replace a Disk Drive” on page 29 Add a node to the storage array. Sun Cluster system administration documentation Remove a node from the storage array. Sun Cluster system administration documentation Sun Cluster 3.0-3.1 With Sun StorEdge 6130 Array Manual • June 2006, Revision A...
  • Page 25: M How To Upgrade Storage Array Firmware

    Remove references to the volumes that reside on the storage array that you are removing. For more information, see your Solstice DiskSuite/Solaris Volume Manager or VERITAS Volume Manager documentation. Chapter 3 • Maintaining a Sun StorEdge 6130 Array...
  • Page 26: Replacing A Node-To-Switch Component

    If yes, and the active path is the path that needs a component replaced, make that path passive. Replace the component. Refer to your hardware documentation for any component-specific instructions. Sun Cluster 3.0-3.1 With Sun StorEdge 6130 Array Manual • June 2006, Revision A...
  • Page 27: M How To Replace A Node-To-Switch Component In A Cluster Without Multipathing

    How to Replace a Host Adapter Use this procedure to replace a failed host adapter in a running cluster. This procedure defines Node A as the node with the failed host adapter that you are replacing. Chapter 3 • Maintaining a Sun StorEdge 6130 Array...
  • Page 28 PatchPro is a patch-management tool that eases the selection and download of patches required for installation or maintenance of Sun Cluster software. PatchPro provides an Interactive Mode tool Sun Cluster 3.0-3.1 With Sun StorEdge 6130 Array Manual • June 2006, Revision A...
  • Page 29: M How To Replace A Disk Drive

    If yes, choose and configure another device to be the new quorum device. Remove the old quorum device. For procedures about how to add and remove quorum devices, see your Sun Cluster system administration documentation. Chapter 3 • Maintaining a Sun StorEdge 6130 Array...
  • Page 30 If yes, use volume manager commands to reattach the submirror or plex. For more information, see your Solstice DiskSuite/Solaris Volume Manager or VERITAS Volume Manager documentation. Sun Cluster 3.0-3.1 With Sun StorEdge 6130 Array Manual • June 2006, Revision A...
  • Page 31 Index replacing, 29-30 adding See also installing disk drives, 23 initiator groups, 17 Ethernet cables, replacing, 23 storage arrays, 16-17 Ethernet hubs, replacing, 23 arrays, See storage arrays expansion cabinets, replacing, 23 batteries, replacing, 24 fan assemblies, replacing, 23 firmware, upgrade storage array firmware, 25 FRUs, 23 cables, replacing, 23 chassis, replacing, 23...
  • Page 32 17 storage arrays, 25-26 storage pools, 17 volume groups, 17 replacing batteries, 24 chassis, 23 controllers, 24 cooling units, 23 disk drives, 29-30 Ethernet cables, 23 Sun Cluster 3.0-3.1 With Sun StorEdge 6130 Array Manual • June 2006, Revision A...