Table 2-4 Power Input Terminal; Table 2-5 Maximum Power/Current Consumption - NF DP060LM Instruction Manual

Programmable ac power source
Table of Contents

Advertisement

2. Preparation before Use
  Check the power source
For safety, use the product in the ranges of input voltage and frequency described below. Connect the
product to a distribution board which provides the power sufficiently higher than the maximum
power consumption of each model (see Table 2-5).
Voltage range: Single-phase input
Three-phase three-wire input 170 V to 250 V
Three-phase four-wire input
Frequency range: 50 Hz/60 Hz 2 Hz
  About power input terminal
Screw
Note: The power input 1P2W is not selectable for DP180LM.
  About power cable
Use a cable of sufficient ampacity for the maximum current consumption (see Table 2-5). A
protective grounding cable should have ampacity higher than or equal to the power cable. For the
optional power cable, see 7.4.
Rated
Model
output
DP060LM
6 kVA
DP120LM
12 kVA
DP180LM
18 kVA
Note: The power input 1P2W is not selectable for DP180LM.
14

Table 2-4 Power Input Terminal

Power input
DP060LM
1P2W
3P3W
M6
3P4W

Table 2-5 Maximum Power/Current Consumption

Maximum
power
Power input 1P2W
consumption
9 kVA
18 kVA
27 kVA
170 V to 250 V
323 V to 433 V (phase voltage 187 V to 250 V)
DP120LM
M8
M6
Maximum current consumption
Power input 3P3W
170 V
170 V
53 A
31 A
106 A
62 A
92 A
PROGRAMMABLE AC POWER SOURCE
DP180LM
M10
Power input 3P4W
323 V
(phase voltage 187 V)
17 A
33 A
49 A

Advertisement