NF DP060LM Instruction Manual page 270

Programmable ac power source
Table of Contents

Advertisement

11. Specifications
*7:For 40 Hz to 550 Hz, sine wave, the rated output voltage, the resistance load for the maximum
current at 55 Hz, and 55 Hz reference.
*8:In the case of the AC mode and 23°C5°C.
Mode
Setting mode
Rated output voltage
Voltage setting range
Setting resolution
Voltage accuracy
(Phase voltage)
*10
Maximum current
(Phase current)
*11
Maximum peak
current
(Phase current)
*12
Short reverse power
flow
*13*14
Power capacity
Load power
factor
Frequency
setting range
Setting resolution
Frequency accuracy
Frequency stability
*15
Voltage frequency
characteristic
*16
Output waveform
Output on phase
setting range
*17
Setting resolution
Output off phase
setting range
*17
Setting resolution
Setting range of the
phase angle
(Unbalanced mode)
Setting resolution
Phase angle accuracy
*18
*19 Within  20 mV (typ. fine adjustment available)
DC offset
252
DP060LM
Single-phase three-wire (1P3W)
Three-phase four-wire (Y-connection) (3P4W)
Floating output, the N-terminal can be grounded.
*9 Balanced mode, Unbalanced mode
100 V / 200 V (phase voltage)
Phase voltage setting (collective for all phases in balanced mode and each
phase in unbalanced mode)
0.0 V to 160.0 V / 0.0 V to 320.0 V
0.0 Vp-p to 454.0 Vp-p / 0.0 Vp-p to 908.0 Vp-p (arbitrary wave)
Line voltage setting (balanced mode and sine wave only)
1P3W: 0.0 V to 320.0 V / 0.0 V to 640.0 V
3P4W: 0.0 V to 277.2 V /0.0 V to 554.2 V
Phase voltage setting: 0.1 V, Line voltage setting: 0.2 V
 (0.5 % of set + 0.6 V / 1.2 V)
20 A / 10 A
Peak value (Apk) which is four times of the
maximum current
100 % or less of Maximum current (RMS)
(reverse power flow time ≦20 ms, discontinuous, 40 °C or lower)
1P3W: 4 kVA
3P4W: 6 kVA
0 to 1 (phase lead or phase lag, 45 Hz to 65 Hz, external power injection and
regeneration are not available.)
40.00 Hz to 550.00 Hz (AC mode)
1.00 Hz to 550.00 Hz (ACDC mode)
0.01 Hz
0.01 % of set (23 °C5 °C)
0.005 %
1 %
sine wave, arbitrary wave (16 types), clipped sine wave (3 types)
0.0° to 359.9° variable (setting resolution 0.1°)
0.1°
0.0° to 359.9° variable (setting resolution 0.1°, active/inactive selectable)
0.1°
1P3W L2 phase: 180° 35.0°
3P4W L2 phase: 120° 35.0°, L3 phase: 240° 35.0°
45 Hz to 65 Hz: 1.0°
40 Hz to 550 Hz: 2.0°
Polyphase output
DP120LM
40 A / 20 A
1P3W: 8 kVA
3P4W: 12 kVA
PROGRAMMABLE AC POWER SOURCE
DP180LM
60 A / 30 A
Peak value (Apk) which
is three times of the
maximum current
1P3W: 12 kVA
3P4W: 18 kVA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp120lmDp180lm