Current *34
Effective
Full scale
value
Resolution
(rms)
Accuracy
DC
Full scale
average
Resolution
value
Accuracy
(avg)
Peak
Full scale
value
Resolution
(pk)
Accuracy
(Reference
(each of
value)
max and
*35
min)
Hold
Effective
Full scale
value
Resolution
(rms)
Accuracy
Peak
Full scale
value
Resolution
(pk)
Accuracy
(Reference
(each of
value)
max and
*35
min)
Hold
*34:The accuracy values are in the case that the output current is 5 % to 100 % of the maximum current.
*35:The accuracy of the peak value is for a waveform of DC or sine wave.
*36:In the polyphase output, it is a specification for phase current, and the DC average value display
cannot be selected.
DP060LM/DP120LM/DP180LM
DP060LM
80 A / 40 A
0.01 A
DC, 45 Hz to 65 Hz
 (0.5 % of rdg
+ 0.16 A / 0.08 A)
40 Hz to 550 Hz
 (0.7 % of rdg
+ 0.16 A / 0.08 A)
80 A / 40 A
0.01 A
DC
 (|0.5 % of rdg|
+ 0.16 A / 0.08 A)
320 A / 160 A
0.01 A
DC, 45 Hz to 65 Hz
 (|2 % of rdg|
+ 0.8 A / 0.4 A)
Holds the maximum values of |max| and |min| with the polarity (with the
clear function)
DP060LM
26.67 A / 13.33 A
0.01 A
DC, 45 Hz to 65 Hz
 (0.5 % of rdg
+ 0.06 A / 0.04 A)
40 Hz to 550 Hz
 (0.7 % of rdg
+ 0.06 A / 0.04 A)
106.67 A / 53.33 A
0.01 A
45 Hz to 65 Hz
 (|2 % of rdg|
+ 0.3 A / 0.2 A)
Holds the maximum values of |max| and |min| with the polarity (with the
clear function)
11.12 Measurement Function
Single-phase output
DP120LM
160 A / 80 A
 (0.5 % of rdg
+ 0.32 A / 0.16 A)
 (0.7 % of rdg
+ 0.32 A / 0.16 A)
160 A / 80 A
 (|0.5 % of rdg|
+ 0.32 A / 0.16 A)
640 A / 320 A
 (|2 % of rdg|
+ 1.6 A / 0.8 A)
Polyphase output *36
DP120LM
53.33 A / 26.67 A
 (0.5 % of rdg
+ 0.11 A / 0.06 A)
 (0.7 % of rdg
+ 0.11 A / 0.06 A)
213.32 A / 106.67 A
 (|2 % of rdg|
+ 0.55 A / 0.3 A)
DP180LM
240 A / 120 A
0.1 A
 (1 % of rdg
+ 0.5 A / 0.3 A)
 (1.4 % of rdg
+ 0.5 A / 0.3 A)
240 A / 120 A
0.1 A
 (|1 % of rdg|
+ 0.5 A / 0.3 A)
960 A / 480 A
0.1 A
 (|2 % of rdg|
+ 2.4 A / 1.2 A)
DP180LM
80 A / 40 A
0.1 A
 (1 % of rdg
+ 0.2 A / 0.1 A)
 (1.4 % of rdg
+ 0.2 A / 0.1 A)
320 A / 160 A
0.1 A
 (|2 % of rdg|
+ 0.8 A / 0.4 A)
257