Dc Output - NF DP060LM Instruction Manual

Programmable ac power source
Table of Contents

Advertisement

*9:Can be set only in the polyphase output.
*10:In the case of 10 V to 150 V/20 V to 300 V, sine wave, no load, 45 Hz to 65 Hz, DC voltage setting
0 V, 23 °C5 °C.
*11:If the output voltage is higher than the rated value, this is limited (lowered) to satisfy the power
capacity. In the case of 40 Hz or lower or 400 Hz or higher, and that the ambient temperature is
40°C or higher, the maximum current may decrease.
*12:For the capacitor input type rectified load (crest factor=4 or 3), the rated output voltage, and 45 Hz
to 65 Hz.
*13:In the case rated output voltage, 50 Hz or 60 Hz. If the output voltage is higher than the rated value,
this is limited to satisfy the power capacity. It may reduce short reverse power flow if ambient
temperature is 40°C or higher or repeated interval of reverse power flow is 15 minutes or less.
*14:External power injection or regeneration which is over short reverse power flow capacity is not
available.
*15:For 45 Hz to 65 Hz, the rated output voltage, no load and the resistance load for the maximum
current, and the operating temperature.
*16:For 40 Hz to 550 Hz, sine wave, the rated output voltage, the resistance load for the maximum
current at 55 Hz, and 55 Hz reference.
*17:Set for the L1 phase. The component of the phase angle setting is added for the other phases.
*18:In the case of 50 V or higher, sine wave, and same load condition and voltage setting for all phases.
*19:In the case of the AC mode and 23 °C5 °C.
11.7

DC Output

[V]=Vdc, [A]=Adc, unless otherwise noted. The polarity is relative to the Lo terminal.
Mode
Rated output voltage
Voltage setting range
Setting resolution
Voltage accuracy
*20
Maximum source
current
*21
Maximum
instantaneous source
current
*22
Short sink current
*23
Power capacity
*20:In the case of −212 V to −10 V, +10 V to +212 V / −424 V to −20 V, +20 V to +424 V, no load, AC
setting 0 V, 23°C5°C.
DP060LM/DP120LM/DP180LM
DP060LM
Floating output, the Lo terminal can be grounded.
100 V / 200 V
227.0 V to +227.0 V / 454.0 V to +454.0 V
0.1 V
 (|0.5 % of set| + 0.6 V / 1.2 V)
60 A / 30 A
Peak value (Apk) which is four times of the
maximum current
100 % or less of Maximum source current
(reverse power flow time ≦20 ms, discontinuous, 40 °C or lower)
6 kW
Single-phase output
DP120LM
120 A / 60 A
12 kW
11.7 DC Output
DP180LM
180 A / 90 A
Peak value (Apk) which
is three times of the
maximum current
18 kW
253