3. Basic Operation
No.
1
External signal input
connector
2
Monitor output connector
3
SYSTEM I/O connector
4
CONTROL I/O connector
5
GPIB connector
or
LAN connector
6
RS232 connector
7
USB connector
8
Air outlet
9
Power input terminal
10
Polyphase output terminal
11
Single-phase output terminal
12
Sensing input terminal
13
Resin-molded cover
14
Status output connector
15
Quick change sync output
connector
16
CONTROL SIGNAL
connector
17
CONTROL IN connector
30

Table 3-2 Component Name (Rear)

Name
Used when controlling the voltage value setting
by the external signal (VCA), when
synchronizing the output frequency with the
external signal (SYNC), and when outputting
the amplified external signal (EXT, ADD).
Can observe waveforms of the output voltage
and output current when connected to a unit
such as oscilloscopes.
Not used.
Used to control this product externally by logic
signal and non voltage contact. Also it can
obtain the state of this product with a logic
signal.
It is connected CONTROL IN connector
(No.17) with the attached control cable (25 pin)
when using DIP or RIN.
GPIB or LAN communication interface.
Either one can be chosen when ordering.
RS232 communication interface.
USB communication interface.
Air outlet for exhausting the heat.
Power input terminal. Power input is 1P2W or
3P3W or 3P4W, either of which can be chosen
when ordering. (The power input 1P2W is not
selectable for DP180LM.) Figure 3-2 shows the
case of power input 3P3W.
Output terminal for the single-phase three-wire
and three-phase four-wire.
Output terminal for the single-phase two-wire.
Connect to the load end that is located in the
distance from the main unit to detect its
voltage. Common among the single-phase
two-wire, single-phase three-wire, and
three-phase four-wire output.
Covers the power input terminal, the sensing
input terminal, the single-phase output terminal
and the polyphase output terminal. When no
load is connected, attach the cover so that the
cutout of the cover comes on the upside.
Output sync signal in quick change operation
and fluctuation test.
It is used as trigger signal to record waveform.
Output sync signal in quick change operation.
It is connected to quick change sync input
connector on DIP.
It is connected to CONTROL SIGNAL
connector on DIP or RIN.
It is connected CONTROL I/O connector
(No.4) with the attached control cable (25 pin)
when using DIP or RIN.
Description
PROGRAMMABLE AC POWER SOURCE
Refer to
4.17,
4.19,
4.20
4.10
-
4.18,
8.1.2,
8.1.3
6.1.3,
6.1.4
6.1.2
6.1.1
2.2
2.4
2.5
2.5
4.11
2.4,
2.5
4.18.1,
4.18.2
4.18.1,
4.18.2,
8.1.2
4.18.2,
8.1.2,
8.1.3
4.18.2,
8.1.2,
8.1.3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp120lmDp180lm

Table of Contents