Ac Output - NF DP060LM Instruction Manual

Programmable ac power source
Table of Contents

Advertisement

11.6

AC Output

[V]=Vrms, [A]=Arms, unless otherwise noted.
Mode
Rated output voltage
Voltage setting range
Setting resolution
Voltage accuracy
Maximum current *2 60 A / 30 A
Maximum peak
current
Short reverse power
flow
*4*5
Power capacity
Load power
factor
Frequency
setting range
Setting resolution
Frequency accuracy
Frequency stability
Voltage frequency
characteristic
Output waveform
Output on phase
setting range
Setting resolution
Output off phase
setting range
Setting resolution
DC offset
*1:In the case of 10 V to 150 V/20 V to 300 V, sine wave, no load, 45 Hz to 65 Hz, DC voltage setting
0 V, 23 °C5 °C.
*2:If the output voltage is higher than the rated value, this is limited (lowered) to satisfy the power
capacity. If there is the DC superimposition, the active current of AC+DC satisfies the maximum
current. In the case of 40 Hz or lower or 400 Hz or higher, and that the ambient temperature is 40°C
or higher, the maximum current may decrease.
*3:For the capacitor input type rectified load (crest factor=4 or 3), the rated output voltage, and 45 Hz to
65 Hz.
*4:In the case rated output voltage, 50 Hz or 60 Hz. If the output voltage is higher than the rated value,
this is limited to satisfy the power capacity. It may reduce short reverse power flow if ambient
temperature is 40°C or higher or repeated interval of reverse power flow is 15 minutes or less.
*5:External power injection or regeneration which is over short reverse power flow capacity is not
available.
*6:For 45 Hz to 65 Hz, the rated output voltage, no load or the resistance load for the maximum current,
and within the operating temperature.
DP060LM/DP120LM/DP180LM
DP060LM
Single-phase two-wire
Floating output, the Lo terminal can be grounded.
100 V / 200 V
0.0 V to 160.0 V / 0.0 V to 320.0 V
0.0 Vp-p to 454.0 Vp-p / 0.0 Vp-p to 908.0 Vp-p (arbitrary wave)
0.1 V
*1  (0.5 % of set + 0.6 V / 1.2 V)
Peak value (Apk) which is four times of the
*3
maximum current
100 % or less of Maximum current (RMS)
(reverse power flow time ≦20 ms, discontinuous, 40 °C or lower)
6 kVA
0 to 1 (phase lead or phase lag, 45 Hz to 65 Hz, external power injection and
regeneration are not available.)
40.00 Hz to 550.00 Hz (AC mode)
1.00 Hz to 550.00 Hz (ACDC mode)
0.01 Hz
0.01 % of set (23 °C5 °C)
0.005 %
*6
1 %
*7
sine wave, arbitrary wave (16 types), clipped sine wave (3 types)
0.0° to 359.9° variable
0.1°
0.0° to 359.9° variable (active/inactive selectable)
0.1°
*8 Within  20 mV (typ. fine adjustment available)
Single-phase output
DP120LM
120 A / 60 A
12 kVA
11.6 AC Output
DP180LM
180 A / 90 A
Peak value (Apk) which
is three times of the
maximum current
18 kVA
251