3. Basic Operation
3.4.7
Setting the Output Frequency
Set the AC component frequency of the internal signal source.
Operation procedure
1. Select the [Freq] item and follow the instructions in 3.3.5 to enter a value.
3.4.8
Setting the Output On/Off Phase
Set the phases when the output turns on/off. After the output-on operation, the voltage output is
started from the output on phase. After the output off operation, the voltage output is completed when
it reaches the output off phase. The output off phase can be disabled. If disabled, the output is turned
off immediately after the operation of output off.
Operation procedure
1. Press the [Osc] soft-key and select [4:On/Off Phs]. The output on/off phase setting window
opens.
52
PROGRAMMABLE AC POWER SOURCE