  Operation procedure
1. Push [Limiter] soft-key to select 2:Irms Limiter (or push I key). Opens the RMS current limiter
set window.
2. Set the value of RMS current limiter in [Io] item.
3. Set the [Output OFF] item as [Enable] or [Disable]. When setting to [Enable], also set the time
from the start of limiter operation to the output off.
4. Close the window.
DP060LM/DP120LM/DP180LM
4.1 Using Limiter, Setting Limiter
67