RMS current limiter
Setting range
(effective value)
Factory default
Resolution
Limiter operation
Setting range
(effective value)
Factory default
Resolution
Limiter operation
Setting ranges and factory defaults when working unit number changed (example)
When the number of working units of DP060LM single-phase output is changed from 3(max.) to 1,
setting ranges and factory defaults of each current limiter become 1/3 of those above. Here is an
example:
Peak current limiter
Positive
Setting range
Factory default
Negative
Setting range
Factory default
RMS current limiter
Setting range
Factory default
DP060LM/DP120LM/DP180LM
DP060LM
3.0 A to 63.0 A /
3.0 A to 31.5 A
63.0 A / 31.5 A
0.1 A
Select whether to recover automatically (continuous) or turn the output off
when the limited state continues over the specified time (1 s to 10 s,
resolution 1 s).
Factory default setting is output OFF when the limit state continues for
10 s.
DP060LM
1.0 A to 21.0 A /
1.0 A to 10.5 A
21.0 A / 10.5 A
0.1 A
Select whether to recover automatically (continuous) or turn the output off
when the limited state continues over the specified time (1 s to 10 s,
resolution 1 s).
Factory default setting is output OFF when the limit state continues for
10 s.
+30.0 A to +252.0 A / +15.0 A to +126.0 A
→ +10.0 A to +84.0 A / +5.0 A to +42.0 A
+252.0 A / +126.0 A → +84.0 A / +42.0 A
252.0 A to 30.0 A / 126.0 A to 15.0 A
→84.0 A to 10.0 A / 42.0 A to 5.0 A
252.0 A / 126.0 A → 84.0 A / 42.0 A
3.0 A to 63.0 A / 3.0 A to 31.5 A
→ 1.0 A to 21.0 A / 1.0 A to 10.5 A
63.0 A / 31.5 A → 21.0 A / 10.5 A
Single-phase output
DP120LM
6.0 A to 126.0 A /
6.0 A to 63.0 A
126.0 A / 63.0 A
Polyphase output
DP120LM
2.0 A to 42.0 A /
2.0 A to 21.0 A
42.0 A / 21.0 A
11.14 Current Limiter
DP180LM
9.0 A to 189.0 A /
9.0 A to 94.5 A
189.0 A / 94.5 A
DP180LM
3.0 A to 63.0 A /
3.0 A to 31.5 A
63.0 A / 31.5 A
261