4. Advanced Operation
3. Set the gain in the [Gain] item.
4.21

Turning the Output On or Off Rapidly

In the factory default settings, the internal output relay of this product is activated linking to the
output on/off. In the output off state, the internal circuit, output terminal, and the outlet of this
product are physically separated. On the other hand, if the output relay chattering causes any problem,
or if you want to turn the output on or off rapidly, you can disable the activation of the output relay.
In that case, the output relay is fixed to the on state and the operation to turn the output on/off is
performed by the semiconductor device. The output off state means the state of high impedance.
Table 4-16 shows the list of the output terminal impedance (reference values in the rear output
terminal) in the output off state when the output relay control is disabled.
Table 4-16 The Output Terminal Impedance in the Output Off State when
DP060LM / DP120LM
Note 1: The reference value of output terminal at rear panel.
Note 2: N indicates the number of the power units energized.
Note 3: For the polyphase output, the value is impedance
186
the Activation of the Output Relay is Disabled
DP180LM
between L1 and N / L2 and N / L3 and N.
100 V range
200 V range
200
k
200
4
N
1
2
200
k
200
12
N
1
6
PROGRAMMABLE AC POWER SOURCE
k
N
1
k
N