4. Advanced Operation
4.18.2

Control of DIP or RIN

Set external control function to DevCtrl and connect between CONTROL I/O connector and
CONTROL IN connector of this product with attached cable (25 pin). You can control DIP or RIN.
When you control DIP, connect the CONTROL SIGNAL connector of this product and DIP and
connect between QUICK CHANGE SYNC OUTPUT connector of this product and QUICK
CHANGE SYNC INPUT connector of DIP with the control cable (37 pin) included in DIP. The quick
change sync signal is output from this product.
At quick change operation and fluctuation test, the sync signal is output from STATUS OUTPUT
connector. It is used as trigger signal to record waveform.
When you control RIN, connect the CONTROL SIGNAL connector of this product and RIN with the
control cable (37 pin) included in RIN.
After the connection turn ON this product and set the external control function to DevCtrl, and then
turn ON DIP or RIN.
-------- Notes ------------------------------------------------------------------------------------------------------------
 It is not able to use CONTROL I/O with control of DIP or RIN at the same time.
 You cannot control DIP or RIN if you turn ON before this product. First of all turn ON this
product.
 You cannot control DIP or RIN if you turn ON not setting external control function of this
product to DevCtrl. After setting to DevCtrl, restart DIP or RIN.
-----------------------------------------------------------------------------------------------------------------------------
 Setting external control function DevCtrl
1. Press the MENU key to move to the root menu, then select [System]. The system setting window
opens.