11. Specifications

11.17 AGC

When the AGC (Automatic Gain Control) is on, the detection point voltage is always measured, and
the output voltage is continuously corrected so that its effective value is equal to the output voltage
setting value. The fluctuation of the detection point voltage can be suppressed even when the load is
fluctuated. The detection point can be switched between the sensing input terminal (remote sensing
on) and the output terminal (remote sensing off). When setting remote sensing to FB, AGC cannot be
set, see 11.16.
Effective only for AC-INT, AC-VCA, AC-SYNC, DC-INT, and DC-VCA and when the waveform is
sine wave or DC. It is turned off when the Sequence or Simulation is selected. It cannot be selected
when the Autocal is set to on.
Response time
Operation range
Calibration range
Accuracy
264
Within 100 ms (typ.)
(DC/50 Hz/60 Hz, at the rated output voltage)
The output voltage setting is 8 V or higher
Within 10 % (difference between the output voltage and measured value)
The output voltage should be within the allowed voltage setting range of the
product.
Within 0.5 V / 1.0 V
(in the case of DC or 40 Hz to 550 Hz, 50 V or higher output voltage, resistance
load, the output current is the maximum current or less)
All models
PROGRAMMABLE AC POWER SOURCE