NF DP060LM Instruction Manual page 274

Programmable ac power source
Table of Contents

Advertisement

11. Specifications
Voltage *30 *31
Effective
Full scale
value
Resolution
(rms)
Accuracy
DC average
Full scale
value
Resolution
(avg)
Accuracy
Peak value
Full scale
(pk)
Resolution
Accuracy
(each of
max and
min)
*30:The accuracy values are in the case that the output voltage is within voltage setting range.
*31:In the polyphase output, it is a specification for phase voltage, and the DC average value display
cannot be selected.
*32:The accuracy of the peak value is for a waveform of DC or sine wave.
Voltage (Line voltage of polyphase output, only with sine waveform output.)
Effective
Full scale
value
(rms)
*33
Resolution
*33:The displayed value is the result of calculation with the phase voltage measured value and the phase
angle setting value regarding the output voltage waveform as a sine wave.
256
Single-phase output
250.0 V / 500.0 V
0.1 V
DC, 45 Hz to 65 Hz
 (0.5 % of rdg + 0.3 V / 0.6 V)
40 Hz to 550 Hz
 (0.7 % of rdg + 0.9 V / 1.8 V)
250.0 V / 500.0 V
0.1 V
DC
 (|0.5 % of rdg| + 0.3 V / 0.6 V)
250.0 V / 500.0 V
0.1 V
*32 DC, 45 Hz to 65 Hz
 (|2 % of rdg| + 1 V / 2 V)
1P3W: 500.0 V / 1000.0 V
3P4W: 433.0 V / 866.0 V
0.1 V
Polyphase output
45 Hz to 65 Hz
 (0.5 % of rdg + 0.3 V / 0.6 V)
45 Hz to 65 Hz
 (|2 % of rdg| + 1 V / 2 V)
Polyphase output
PROGRAMMABLE AC POWER SOURCE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp120lmDp180lm

Table of Contents