11. Specifications

11.21 Clipped Sine Wave

The peak clipped sine wave can be output, based on the crest factor (CF) setting or the percent setting
to the peak value.
Number of memories
CF
Variable range
*56 *57
Factory default
Setting resolution
Effective value correction
Clip ratio
Variable range
*56 *58
Factory default
Setting resolution
Effective value correction
*56:In the polyphase output, it is the setting for phase voltage.
*57:The crest factor is represented as "voltage peak value/voltage effective value." It is 1.41 for sine
wave.
*58:When the clip ratio is specified, the peak is clipped by the voltage corresponding to the specified %
to the peak value of the setting voltage (100 %).
Example) For the output voltage setting of 100 Vrms and the clip rate of 80 %, the peak is clipped at
113.1 Vpk.

11.22 Arbitrary Wave

This uses the waveform data saved in the internal memory, which is transferred and recalled using the
external interface or USB memory.
Number of memories
Waveform length
Amplitude resolution
268
3 (non-volatile)
1.10 to1.41
1.41
0.01
Yes
40.0 % to100.0 %
100.0 %
0.1 %
None
16 (non-volatile)
4096 words
16 bit
All models