10.5

AC Output

[V]=Vrms, [A]=Arms, unless otherwise noted.
DP series
DP series Type R
Mode
Setting mode
Rated output voltage
Voltage setting range
Setting resolution Phase voltage setting: 0.1 V, Line voltage setting: 0.2 V
Voltage accuracy *3
Maximum current *4
Maximum peak
current
Reverse power flow
(only for Type R) *6
Power capacity
Load power factor
Frequency
setting range
Setting resolution 0.01 Hz
Frequency accuracy
Frequency stability*8
Voltage frequency
characteristic
Output waveform
Output on phase
setting range
*10
Setting resolution
Output off phase
setting range
*10
Setting resolution
Phase angle
setting range
(Unbalanced mode)
Setting resolution
Phase angle accuracy
*11
DC offset
*12
*1:
Only when polyphase system is configured with single-phase model.
*2:
Line voltage setting only when polyphase system is configured with single-phase model.
DP Series/DP Series Type R
Single-phase model and Single-phase output of Multi-phase model
015S
030S
015RS
030RS
Single-phase two-wire
Floating output, the Lo terminal can be grounded.
*1
Balanced mode, Unbalanced mode
100 V / 200 V
Phase voltage setting (for all phases in balanced mode and each phase in
*2
unbalanced mode)
0.0 V to 160.0 V / 0.0 V to 320.0 V
0.0 Vp-p to 454.0 Vp-p / 0.0 Vp-p to 908.0 Vp-p (arbitrary wave)
Line voltage setting (balanced mode and sine wave only)
0.0 V to 320.0 V / 0.0 V to 640.0 V (1P3W)
0.0 V to 277.2 V / 0.0 V to 554.2 V (3P4W)
(0.5 % of set + 0.6 V / 1.2 V)




Peak value (Apk) which is four times of the maximum current
*5
40 % (continuous, 30 °C to 40 °C) of maximum current (phase current, RMS)
50 % (continuous, lower than 30 °C) of maximum current (phase current, RMS)
100 % (reverse power flow time  180 s, reverse power flow duty  0.2, 40 °C or
lower) of maximum current (phase current, RMS)
*7
1.5 kVA
3 kVA
DP series
0 to 1 (Phase lead or phase lag, 45 Hz to 65 Hz, external power injection or
regeneration are not available.)
DP series Type R
−1 to +1 (Phase lead or phase lag, 45 Hz to 65 Hz)
40.00 Hz to 550.00 Hz (AC mode)
1.00 Hz to 550.00 Hz (ACDC mode)
0.01 % of set (23 °C5 °C)
0.005 %

*9
sine wave, arbitrary wave (16 types), clipped sine wave (3 types)
0.0° to 359.9° variable
0.1°
0.0° to 359.9° variable (active/inactive selectable)
0.1°
L2 phase: 0° to 359.9° (1P3W)
*1
L2 phase: 0° to 359.9°, L3 phase: 0° to 359.9° (3P4W)
0.1°
45 Hz to 65 Hz: 1.0°
40 Hz to 550 Hz: 2.0°
Within 20 mV (typ., fine adjustment available.)
045S
060S
075S
045M
045RS
060RS
075RS






4.5 kVA
6 kVA
7.5 kVA
10.5 AC Output
090S
105S
120S
090M
090RS






9 kVA
10.5kVA
12 kVA
271