Output Examples Using Simulation Function; Figure 4-12 Voltage Dip Simulation Example - NF DP015S Instruction Manual

Dp series programmable ac power source
Hide thumbs Also See for DP015S:
Table of Contents

Advertisement

4. Advanced Operation
phase opens.
The stop phase can be set at the Normal 1, Normal 2, and Abnormal steps. For other steps, the stop
phase is fixed to OFF and cannot be specified.
 Trigger output (Trig Out)
State output to CONTROL I/O connector. This specifies whether the trigger output presents when
the step starts. Polarity and pulse width of the trigger output complies to the trigger output setting
(see 4.3.5). At the Initial Step, the trigger output cannot be specified and thus no trigger is output.
 Step sync code output (Code)
State output to CONTROL I/O connector. Code to output while the execution of the step, which is
specified by 2-bit H/L. The step synchronization code can be specified also at the Initial Step.
 Repeat (Repeat)
You can set to repeat the simulation in a series from the Normal 1 step to the Normal 2 step. Specify
the ON or OFF of repeat and the repeat count. When Repeat is set to ON, the simulation repeats for
the specified count. The simulation in a series is repeated for the repeat count + 1. Setting the repeat
count to zero (0) means an infinite count. When Repeat is set to OFF, the DP Series executes the
simulation only once and finishes it without performing the repeat operation.

4.3.3 Output Examples Using Simulation Function

 Voltage dip simulation
In this simulation, the 50 Hz 100 V power source repeats a 70% voltage dip for 0.5 seconds three
times at 10-second intervals as shown in Figure 4–12. For this case, set so that the total of Normal 1
and Normal 2 Step Times becomes 10 seconds and set the repeat count to 3. Set the Trans 1 and
Trans 2 Step Times to zero (Table 4-6).
At dipping
ディップ時
70 V
5 second
5秒
0.5秒
0.5
second
106
At normal
正常時
100 V
5 second
5秒
Repeat 3 times
3回繰り返し

Figure 4-12 Voltage Dip Simulation Example

Frequency: 50Hz
PROGRAMMABLE AC POWER SOURCE
周波数: 50 Hz