Control Of Dip - NF DP Series Instruction Manual

Programmable ac power source
Table of Contents

Advertisement

4. Advanced Operation

4.18.2 Control of DIP

Set external control function to DevCtrl and you can control DIP.
Connect between the CONTROL I/O connector of this product and the CONTROL SIGNAL
connector of DIP with the attached control cable (25 pin-37 pin +BNC) and connect the BNC
connector of the control cable to the QUICK CHANGE SYNC INPUT connector. The quick change
sync signal is output from this product.
After the connection turn ON this product and set external control function to DevCtrl, and then turn
ON DIP.
-------- Notes ------------------------------------------------------------------------------------------------------------
 It is not able to use CONTROL I/O with control of DIP at the same time.
 You cannot control DIP if you turn ON before this product. First of all turn ON this product.
 You cannot control DIP if you turn ON not setting external control function of this product to
DevCtrl. After setting to DevCtrl, restart DIP.
-----------------------------------------------------------------------------------------------------------------------------
■Setting external control function to DevCtrl
1. Press the MENU key to move to the root menu, then select [System]. The system setting window
opens.