M800VS/M80V Series Connection and Setup Manual
6 Precautions for Connecting
6.1 Precautions for Wiring

6.1.2 Precautions for Using Optical Communication Cable

An optical communication cable is used for communication between the control unit and the drive unit.
Special precautions, differing from the conventional cable, are required when laying and handling the optical communication
cable.
Note
(1) If the cable you use is not Mitsubishi's, malfunctions resulted from connection problems or aged deterioration are not cov-
ered under the warranty.
Optical communication cable outline and parts
Fiber code/connector connection section
Optical connector
22.7
To ensure the system performance and reliability, purchase the optical communication cable from Mitsubishi. A machining
drawing is given in "Cable" as reference, but the purchased optical communication cable cannot be cut or connected by the
machine tool builder.
Precautions for handling optical communication cable
(1) A protective cap is attached to the optical module and optical communication cable mounted on the PCB when the sys-
tem is delivered. Leaving this protective cap unattached could result in connection faults from the adherence of dirt and
dust. Do not remove the protective cap when not connecting the cable. If dirty, wipe off lightly with a piece of dry gauze,
etc. (Do not use solvents such as alcohol as the optical fiber material could melt.)
(2) Hold the connector section when connecting or disconnecting the optical connector. Holding the fiber cord will result in
force exceeding the tolerable tension on the fiber cord and connector connection section, and could cause the fiber cord
to dislocate from the optical connector thereby inhibiting use.
(3) The optical connector cannot be connected in reversed. Check the connector orientation when connecting the optical
communication cable to the optical module. Align the connector lock lever with the lock holes on the PCB's optical mod-
ule, and press the connector straight in. Confirm that the lock lever connects with the optical module and that a "click" is
heard.
(4) When disconnecting the optical communication cable from the PCB, press the lock release buttons on the lock lever, and
pull out the cable while holding the connector section. The connector could be damaged if the cable is pulled without
pressing down on the lock release buttons.
(5) Do not apply excessive force onto the optical communication cable by stepping on it or dropping tools, etc., on it.
Fiber cord
150
35
213
Bushing
Reinforced
sheath
IB-1501613-A