Connecting The Batteries; Control Unit Battery - Mitsubishi Electric M800VS Series Connection And Set Up Manual

Hide thumbs Also See for M800VS Series:
Table of Contents

Advertisement

M800VS/M80V Series Connection and Setup Manual
17 Setting the Hardware

17.5 Connecting the Batteries

17.5 Connecting the Batteries

17.5.1 Control Unit Battery

CAUTION
The battery is not connected when the machine is delivered. Be sure to connect the battery before starting up.
Lithium batteries in the control unit battery holder retain parameters, machining programs and other data which require
backing up at power OFF.
Battery
Battery cumulative data holding time 45,000 hours (At 0 to 45 °C. The life will be shorter if the temperature is high.)
Battery life
[Precautions for handling battery]
 Do not disassemble the battery.
 Do not place the battery in flames or water.
 Do not pressurize and deform the battery.
 This is a primary battery so do not charge it.
CAUTION
Do not short-circuit, charge, overheat, incinerate or disassemble the battery.
IB-1501613-A
Q6BAT
Approximately 5 years (from date of battery manufacture)
382